GreenPonik Programme Bêta Test

Sommaire

  1. Parts list
  2. Typical setup
  3. Module IO
  4. Wiring
  5. WaterPump IO
  6. First Use - Hardware
    6.1 Module installation
  7. First Use - Software
    7.1 Wifi setup
    7.2 Device update
    7.3 Greenponik account setup
    7.4 Read values
    7.5 Set a target
    7.6 Turn auto-dosing ON/OFF
    7.7 Sensor calibration
  8. Pumps
    8.1 Dosage setup
    8.2 Prime tube
    8.3 Clean tube
    8.4 Manual dosage
    8.5 Nutrients counter
    8.6 Container tube length
  9. Misc.
    9.1 Device reboot/shutdown
    9.2 Send debug logs to us
    9.3 Reset Wifi network


Parts List

  • 1x Water Sensor
    water Sensor Image
  • 1x Water Pump
    Water Pump Image
  • 1x EC Sensor + 1x pH Sensor + 2x Cable Holder
    ec and ph probes Image
  • 1x Water Sensor PowerSupply + 1x USB Cable + 1x Module link cable
    5v power supply Image
  • 1x Water Pump Power Supply
    12v power supply Image
  • 1x EC/pH sensor floater
    probe's floater Image
  • 1x Water Pump I/O tubes
    Water Pump I/O tubes Image
  • 1x pH solution tube (smaller one) + 2x EC solution tube with check valve
    Solutions Tubes Image
  • 1x mix pump and solution injector
    Mix Pump Image
  • 1x Tube/Cable Hook
    Hook Image
  • 2x Wall Mount
    Wall Mounts Image
  • 5x Screw for wall mont
    Wall Mount's Screws Image
  • 1x Wifi socket for irrigation control
    Wifi Socket Image
  • 1x Spare parts bag
    Spare parts bag Image
  • 1x Plug Adapters (outside EU standard countries)
    Plug Adapter Image


Typical Setup

This setup is designed for the Beta version and will be optimized before release.
typical setup Image

  1. WaterSensor
  2. WaterPump
  3. Nutritive solution containers
  4. PH sensor
  5. EC/temp. sensor
  6. Mix pump
  7. User’s irrigation pump
  8. Wifi socket
  9. WaterSensor power supply
  10. WaterPump power supply

Module IO

Here are details of the I/O. Connector types/number and placement will be optimized for the final version.

module io image

  1. EC/temp sensor (jack 3.5mm)
  2. Water sensor USB power supply
  3. Module link cable
  4. Manual button
  5. EC/temp. sensor (BNC)
  6. PH sensor

module io image

  1. Module link cable
  2. WaterPump power supply

Wiring

Here is a detail of each cable: 1 cable = 1 color. You can’t make a mistake as each cable has one type of connector it can go in.

wiring image

  • pH sensor
  • EC/Temp. sensor
  • WaterPump Input
  • WaterPump Output
  • Containers Tubes
  • WaterSensor power supply
  • WaterPump power supply
  • Module Link cable
  • Your irrigation pump
  • Mix pump

Water Pump IO

The Beta WaterPump is equipped with 4 peristaltic pumps. Those pumps are interesting because they can pump water, air, a wide range of viscosity, are accurate, can be easily maintained and are reliable! Final version will allow multiple WaterPump modules up to 20 pumps!

water pump io image

  1. Water pump
  2. PH pump
  3. EC 1/A pump
  4. EC 2/B pump
  5. Solution injection circuit input
  6. PH solution input
  7. EC 1/A solution input
  8. EC 2/B solution input
  9. Solution injection circuit input

First Use Hardware

Module Installation

  • Screw the 2 wall mounts (1 & 2) on your support without too much force so the part doesn’t break.
    install step 1 image

  • Insert both modules (1 & 2). You can use both wall mounts as those are the same for both devices. Prepare your container support (3), leave 30-35cm between the WaterPump and your container support.
    install step 2 image

  • Plug the PH probe (1 - BNC).
    install step 3 image

  • Plug the first EC connector (1 - BNC).
    install step 4 image

  • Plug the second ECconnector (1 - jack 3.5mm).
    install step 5 image

  • Plug the module link cable on both modules (1).
    install step 6 image

  • Plug the WaterPump power supply (1 - jack 5.1mm).
    install step 7 image

  • Plug the WaterSensor power supply (1).
    install step 8 image

  • Plug the WaterSensor power supply(1 -USB).
    install step 9 image

  • Insert the EC sensor in the Sensor Floater (1). Leave approximately 1cm between the plastic cap and the floater and remove the cap.
    install step 10 image

  • Insert the PH sensor in the sensor floater.The protection cap (1) should be near the floater and the sensing part must be the same side as the EC sensor’s.
    install step 11 image

  • Remove your container caps (1).
    install step 12 image

  • Drill a 6mm hole in your container caps (1).!!! Be very careful not to arm yourself with the tool you’ll use !!!
    install step 13 image

  • Insert each container solution tube in your drilled container caps. The check valve of the EC tubes must be pointing inside the container (1).
    install step 14 image

  • Screw the container caps (1).
    install step 15 image

  • Plug each solution tube (1) this way:
    • PH to pump number 2 (small white connector)
    • EC 1/A to pump number 3 (bigger black connector)
    • EC 2/B to pump number 4 (bigger black connector)

      install step 16 image

  • Insert the small WaterPump IO tube in the Mixer Pump’s smaller hole. Insert it until you feel the stop (1). Be careful not to go too far as it would block the WaterPump inlet, thus blocking regulation…
    install step 17 image

  • Insert the large WaterPump IO tube in the Mixer Pump’s larger hole. Insert it until you feel the stop (1). Again, be careful not to go too far as it would block the WaterPump inlet, thus blocking regulation…
    install step 18 image

  • Install the Mix Pump in your water tank. You can let it float freely as long as it’s able to spread the solutions uniformly from the pump output. Adjust the flow knob if it’s too strong for your water volume so that it doesn’t spread water out of the water tank (1).
    install step 19 image

  • Place the Sensor Floater in your water tank with the sensor parts facing down (1).
    install step 20 image

  • If you need to, you can Install the tube/cable hook (1) on the side of your water tank as high as you can. It’s not mandatory as certain water tank won’t allow its use.
    install step 21 image

  • Connect the WaterPump input and output on the WaterPump side. The small tube goes on the left (1) and the large one on the right (2).
    install step 22 image

  • Plug the Wifi power socket (1) and plug your irrigation pump in it (2).(beta-tester outside of EU standard must use the provided socket adapters).
    install step 23 image

  • Fill up your water tank (1) and be sure that the Sensor Floater is in a flat position, sensor parts facing down.
    install step 24 image

  • Plug the WaterPump (1) and Mix Pump (not shown). (beta-tester outside of EU standard must use the provided power socket adapters).
    install step 25 image


And this is all for the hardware installation, Now it’s time to connect your Smartphone or computer to your device. For this you have 2 solutions.

install step 26 image

Scan the QR code below to watch our Youtube tutorial.

install step 27 image
Or continue in the next section

First Use Software

Wifi Setup

Device Update

GreenPonik Account Setup

Pumps

Mics

Reboot Shutdown

Send Debug

Reset Wifi

QR code chaine youtube de GreenPonik